Cold site

3.3 Explain disaster recovery (DR) concepts

DR Sites

📘CompTIA Network+ (N10-009)


Cold Site in Disaster Recovery (DR)

A Cold Site is a type of backup location used in disaster recovery planning. It is one of the three main types of DR sites: Cold Site, Warm Site, and Hot Site. Each type is designed to help an organization recover after a disaster, but they differ in readiness and cost.

Definition

A Cold Site is a backup facility that has the physical infrastructure (like the building, power, cooling, and network connections) but does not have live servers, applications, or data ready to use. It’s essentially an empty shell or space that can be quickly equipped with the necessary IT resources when a disaster occurs.


Key Characteristics of a Cold Site

  1. Infrastructure only:
    • The site provides space, power, cooling, and network connectivity.
    • It does not have servers, storage, or software installed.
  2. No pre-installed data:
    • All systems, applications, and data backups must be brought in and set up after the disaster happens.
  3. Lower cost:
    • Cold sites are cheaper than warm or hot sites because you only pay for the space and basic infrastructure, not for active hardware or staffing.
  4. Longer recovery time:
    • Since you need to install hardware, restore data, and configure systems, recovery can take days or weeks, depending on the complexity.
  5. Testing:
    • Organizations can test their DR plan by setting up systems at the cold site, but it’s more resource-intensive than testing at warm or hot sites.

How It Works in an IT Environment

Imagine a company has its main data center, but a disaster (like a fire, flood, or cyberattack) destroys it. Here’s what happens with a cold site:

  1. The company has a contract for a cold site at a secure location.
  2. After the disaster, IT staff bring in servers, storage, and networking equipment.
  3. They restore backups of databases, applications, and configurations.
  4. Users are redirected to the cold site, and business operations resume, though more slowly than normal.

Important points for the exam:

  • Cold sites are used for DR, not day-to-day operations.
  • They are cheaper but slower to activate.
  • They require data backups and hardware to be functional.
  • Suitable for organizations that can tolerate downtime of hours or days.

Comparison with Warm and Hot Sites

FeatureCold SiteWarm SiteHot Site
Hardware & softwareNoneSome pre-installedFully equipped and live
Data availabilityNonePartial backupsUp-to-date, real-time
CostLowMediumHigh
Recovery timeLong (days/weeks)Medium (hours)Very short (minutes/hours)
StaffingOnly when activatedSome staff pre-allocatedFully staffed 24/7

Exam Tips

  • Remember: Cold = Cheap + Empty + Slow
  • Know the order: Hot → Warm → Cold in terms of cost and recovery speed.
  • Cold sites are suitable when business downtime is acceptable.
  • Often used by small to medium-sized organizations to save costs.
  • Key phrase for exam: “A cold site is a backup facility with infrastructure but without live IT systems or current data.”

This covers everything you need to know about Cold Sites for the CompTIA Network+ exam, in simple IT-focused language.